Finisher Sensor Test

This test determines if the finisher sensors are working correctly. The sensors that are tested include the following:
Bin Level
Finisher Bin Empty
Bin Full sensor
Bin Near Full
Cover and Door
Side Door sensor
Pass and Media
Finisher Passthru
Media sensor
Staple Sensors
Cartridge Presence sensor
Staple Low sensor
Self-priming sensor
Home Signal sensor
From the Diagnostics menu, navigate to: FINISHER TESTS > Finisher Sensor Test.
When you select a Sensor group such as Bin Level from the menu, Bin Level Testing... appears, and the
sensors in that group are polled.
After the sensors are polled, you can manually actuate each of the sensors. When the sensor is closed, Closed
appears; when the sensor is open, Open appears.
To exit the sensor test, press Stop (X) or touch Back.

BASE SENSOR TEST

Use the Base Sensor Test to determine that the sensors located inside the printer are operating correctly.
The following sensors can be checked using this test:
Input
Fuser exit
Narrow media
Control panel interlock
MPF media present
Rear door interlock
Rear lower door interlock
CAUTION—SHOCK HAZARD: Do not use your hand to toggle these switches. Use a nonconducting item.
To run the Base Sensor Test.
1
From the Diagnostics menu, navigate to BASE SENSOR TEST.
2
Choose a sensor.
3
Manually actuate the sensor to verify that it toggles. If the sensor does not toggle, then it is malfunctioning.
Service menus