Removing The Master End Sensor; Removing The Tph Ass'y - Riso V8000 Series Technical Manual

Table of Contents

Advertisement

CHAPTER 14. MASTER MAKING SECTION
5.

Removing the Master End Sensor

(1) Remove the master making unit lower cover ass'y.
(2) Remove the master end sensor together with the master end sensor cover. (M3 x 6 screw)
(3) Remove the mounting screw (M3 x 6), then remove the master end sensor.
P1412
6.

Removing the TPH Ass'y

(1) Remove the master making unit lower cover ass'y.
(2) Detach the ground wire. (M3 x 6 screw)
(3) Remove the two mounting screws (M3 x 6), disconnect the two connectors, and remove the TPH
ass'y.
[Precautions for Reassembly]
1. Align the half-pierced section with the hole in the TPH ass'y shaft.
2. If the TPH is replaced, enter the new TPH registance value using
TPH ass'y shaft
Master end sensor cover
Connectors
TPH ass'y
[14 - 8]
Master end sensor
Test Mode No.288.
Ground wire
P1414
P1413
P1415

Advertisement