CHAPTER 14. MASTER MAKING SECTION

Disassembly

1.

Removing the Master Volume Detection Sensor (Receive/Send)

(1) Open the scanner table.
(2) Open the master making unit and remove the master roll.
(3) Remove the volume detection sensor (receive) bracket and volume detection sensor (send) bracket.
(One M3 x 6 screw each)
(4) Remove the mounting screw (M3 x 6) on the master volume detection sensors (receive) and (send),
disconnect the connectors, and remove the sensors.
Master making unit
Scanner table
Master roll
Volume detection sensor (receive) bracket
Volume detection sensor (send) bracket
[14 - 4]