Warnings (requiring service calls)
Error type
E01 [Replace ROSE battery]
!!Battery Replacement!!
Panel display
Call Service
Reset method
Press the "Close" button, the "Stop" key, or the "Reset" key.
Error point
Battery detection signal was OFF after power was switched on, reset, or after operation.
039
(The voltage of battery goes down under 2.5V)
Error type
E02 [Maintenance call]
!!Maintenance!!
Panel display
Call Service
Reset method
Press the "Close" button, the "Stop" key, or the "Reset" key.
Error point
Displays when machine power ON or All-Rest is pressed after master making quantity
042
reached set quantity by test mode.
Displays when machine power ON or All-Reset is pressed after printing quantity reached set
043
quantity by test mode.
Displays when machine power ON or All-Reset is pressed after print drum No.1
044
maintenance counter reaches set number by test mode.
Displays when machine power ON or All-Rest is pressed after print drum No.2 maintenance
045
counter reaches set number by test mode.
Error type
E03 [Replace MCTL PCB battery]
!!Battery Replacement!!
Panel display
Call Service
Reset method
Press the "Close" button, the "Stop" key, or the "Reset" key.
Error point
Battery detection signal was OFF after power was switched on.
047
(The voltage of battery goes down under 2.5V)