Riso V8000 Series Technical Manual page 284

Table of Contents

Advertisement

Error type
A05 [1st master present in master disposal section]
A05-***
Panel display
Master Jammed in Disposal Unit
Pull Out Print Drum 1 and Remove Master
Pull out 1st print drum (The 1st print drum set sensor switches OFF and the 1st print drum
Reset method
connection signal switches OFF) and 1st master disposal jam sensor is OFF.
Error point
336
Master disposal jam sensor was ON at the start of master making.
Error type
A06 [Check paper feed tray]
A06-***
Panel display
Check Standard Feed Tray
Reset method
Switch OFF the paper feed tray safety SW.
Error point
431
Paper feed tray safety SW was ON.
Error type
A16 [Awaiting master removal]
A16-***
Panel display
Master Remains on Print Drum 2
Pull Out Print Drum 2 and Remove Master
Reset method
Remove the master. (Master positioning sensor: OFF)
Error point
Master positioning sensor does not switch OFF after the user master cutting operation. (Cut
256
master is not removed.)
Error type
A18 [1st print drum unlocked]
A18-***
Panel display
Print Drum 1 has been Unlocked
To Lock it Again, Pull it Out and Set it Back in Place
Pull out the 1st print drum. (1st print drum set sensor switches OFF and 1st print drum
Reset method
connection signal switches OFF.)
Error point
561
Print drum lock was released for drum removal.
Error type
A19 [2nd master loading error]
A19-***
Panel display
Master Jam
Pull Out Print Drum 2 and Remove Master
Pull out 2nd print drum. (2nd print drum set sensor switches OFF and 2nd print drum
Reset method
connection signal switches OFF.)
Error point
231
Master loading sensor does not go ON during master loading.
Error type
A20 [2nd master disposal error]
A20-***
Panel display
Master Disposal Error
Pull Out Print Drum 2 and Remove Master
Pull out 2nd print drum. (2nd print drum set sensor switches OFF and 2nd print drum
Reset method
connection signal switches OFF.)
Error point
Master disposal jam sensor does not go ON when disposal is complete (after the master
331
disposal motor stops).
Master disposal jam sensor does not switch OFF when master compression ends (after the
332
fourth compression).
CHAPTER 16. PANEL MESSAGES
DETAILED LIST OF PANEL MESSAGES
Error conditions
Error conditions
Error conditions
Error conditions
Error conditions
Error conditions
[16 - 21]

Advertisement

Table of Contents
loading

Table of Contents