CHAPTER 16. PANEL MESSAGES
DETAILED LIST OF PANEL MESSAGES
Error type
Panel display
Reset method
Error point
621
622
624
625
Error type
Panel display
Reset method
Error point
301
304
305
306
Error type
Panel display
Reset method
Error point
201
202
203
204
T11 [1st pressure control motor lock]
T11-***
!!System Error!!
Press Reset Key.
If Recovery has Failed, Call Service
Press the [OK] key or the Reset button, or switch on power once again.
Print pressure HP sensor does not go ON within the preset interval during print pressure
initialization. (To identify a defect in the sensor itself)
Pressure HP sensor does not switch OFF within the preset interval when the motor rotates
from HP sensor ON.
Print pressure limit sensor does not change within the preset interval after the motor starts
(initial status) during the print pressure limit count. (for motor lock detection)
Print pressure limit sensor does not change within the preset interval during the print
pressure limit count (after leaving initial status). (for motor lock detection)
T12 [1st master disposal compression motor lock]
T12-***
!!System Error!!
Press Reset Key.
If Recovery has Failed, Call Service
Press the [OK] key or the Reset button → recovery operation (HP resetting), or switch on
power once again.
Master compression HP sensor does not go ON within 7 s when the master compression
plate returns.
Master disposal upper limit sensor does not go ON within 7 s when the master
compression plate performs compression.
Overload current detected when the master compression plate returns.(It is not monitored
between 300msec after motor ON.)
Both the master compression limit sensor and master compression HP sensor are ON at
the start of the operation.
T13 [Cutter motor lock]
T13-***
!!System Error!!
Press Reset Key.
If Recovery has Failed, Call Service
Press the [OK] key or the Reset button → recovery operation (HP resetting), or switch on
power once again.
Cutter HP sensor does not go ON within 0.5 s when the cutter motor operates.
Cutter HP sensor does not switch OFF within 0.5 s when the cutter motor operates.
A03 occurs even when cutting is repeated.
Cutter HP switch is OFF when the cutter motor tries to operate.
Error conditions
Error conditions
Error conditions
[16 - 8]