Pitney Bowes relay 3000 Operator's Manual page 86

Document inserting system with a standard control panel
Hide thumbs Also See for relay 3000:
Table of Contents

Advertisement

6 • Troubleshooting and Error Messages
5. Remove it from its mounting bar
and discard the old felt.
6. Install the new upper felt. Locate
the tabs on the back of the felt
assembly in the corresponding
holes of the mounting bar and
slide the felt toward the rear of
the machine. Make sure it has
fully latched into position.
7. Using the plastic tweezers
provided in the kit, remove all
four felts from the sealer tank.
Discard these old felts.
8. Install the four new felts into the
sealer tank. They will only fit one
way. Push them fully down into
the tank.
9. Push down on the blue tab to
return the upper felt assembly to
its operating position. Make sure
that the blue latches (A) spring
out and fully latch into position.
10. Put the water bottle back into
position and close the covers.
6-8