1: On
2966*
Drum Conditions: Periodic Adjustment Interval Setting
Sets the time interval between automatic adjustments.
002
[1 to 24/24/1 hour]
2967*
Developer Density Adjustment Mode
Determines whether the amount of toner is checked during auto process control
with only the TD sensor. With this feature on, the machine uses the TD sensor
only.
[0 to 1/1]
0: Off
1: On
During auto process control execution after the main switch is turned on, the
toner amount in the development unit is normally checked and adjusted using
the ID sensor. However, in some environments, such as where there could be
traces ammonia in the air, copies could appear dirty or too dark because the ID
sensor reading is not reliable.
2968
Toner Exit Mode
Press Execute to force used toner into the toner collection bottle. The moving
components of the cleaning and toner collection areas will rotate for about 60
sec. with the transfer belt released.
2969*
Toner Bottle Revolution
001 Copy Count Setting
002 Count Reset
SM Appendix
Sets the standard number of copies by using the number
of toner bottle rotations. DFU
[50 to 500/100/1]
Press "Execute" to reset the toner bottle rotation count.
DFU
4-37