Ricoh D065 Service Manual page 100

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Punch Unit (B531)
12. At the front, secure the punch unit [A] with the large step screw (
13. Attach the punch unit knob [B] (
14. Connect the PCB harness connector [A] to CN129 of the finisher PCB and to CN600 of
the punch unit PCB.
15. Connect the HP Sensor 2 harness connector [B] to CN130 of the finisher PCB and to
HP Sensor 2.
16. Connect the single end of the hopper full sensor connector cable [C] to the hopper full
sensor on the arm (
Sensor 1 [D] and CN620 [E] of the punch PCB.
D062/D063/D065/D066
x 1).
x 1,
x 1), then connect the other two connectors to HP
2-52
x 1, M4 x 10).