Humidity Thresh: Trans. Bias
002
[0 to 100 / 70 / 1%]
2902
Test Pattern Printing
Test Pattern
Produces the printer test patterns. (See "Test Pattern Printing" in the Main
003
Chapters.)
[0 to 26 / 0 / 1]
2906*
TD Sensor Control Voltage and Check
001 TD Sensor Control Voltage
Adjustment mode for production. DFU
[4.0 to 12.0/9.7/0.1 V]
002 Auto Adjust Set
Displays the TD sensor data stored when SP2801 (TD Sensor Initial Settings) is
executed.
[4.0 to 12.0/9.7/0.1 V]
2909*
Main Scan Magnification
001 Copy
Adjusts magnification in the main scan direction for copying.
[–2.0 to +2.0/0/0.1%]
2910*
Writing Sub Scan
Adjusts magnification in the main scan direction for copying.
001
[–1.0 to +1.0/0/0.1%]