Ricoh D065 Service Manual page 515

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Service Call Conditions
Printer ready error
The print ready signal is not
964
D
generated for more than 17
seconds after the IPU received
the print start signal.
Print image data transfer error
After a data transfer begins from
984
D
the controller to the engine via
the PCI bus, the transfer does
not end within 15 s.
Scanned image data transmission error
After a data transfer begins from
985
D
the engine to the controller via
the PCI bus, the transfer does
not end within 3 s.
Software error 1
The write parameter received by
986
D
the write module at the beginning
of the setting table is NULL.
Software Performance Error 1
An unexpected operation was encountered by the software.
Software crash, reboot the machine
990
B
If the HDDs have just been replaced, be sure to download the stamp
data (SP 5853).
With SP5990 004(SMC Report – Logging Data), print the most recent
information for SC990.
D062/D063/D065/D066
Software defective
Controller (SIMAC) board defective
BICU defective
BICU/controller disconnected
Controller (SIMAC) board defective
BICU defective
BICU/controller disconnected
Controller (SIMAC) board defective
BICU defective
BICU/controller disconnected
3-70
GW
SM Appendix