Service Call Conditions
833
D
Self-diagnostic error 8: Engine I/F ASIC
ASIC (Mandolin) for system
control could not be detected.
0F30
After the PCI configuration, the
0F31
device ID for the ASIC could not
be checked.
The read/write check done for
resident RAM on the mother
0F41
board could not be done
correctly.
Could not initialize or read the
50B1
bus connection.
Value of the SSCG register is
50B2
incorrect.
834
D
Self-diagnostic error 9: Optional Memory RAM DIMM
The write/verify check for the
optional RAM chip on the
5101
engine mother board gave an
error.
Self-diagnostic Error: Clock Generator
A verify error occurred when setting
838
D
data was read from the clock
generator via the I2C bus.
D062/D063/D065/D066
ASCI (Mandolin) for system control
is defective
Interface between North Bridge and
AGPI is defective
Replace the mother board
Memory device defective
Replace the mother board
Bus connection defective, loose
SSCG defective
Replace the mother board
Bus connection loose, defective
SSCG defective
Replace the mother board
Controller defective
Mother board defective
Replace the controller board