Service Call Conditions
Self-diagnostic error: HDD
3003
822
B
3004
3013
3014
D062/D063/D065/D066
Check performed when
HDD is installed:
HDD device busy for
over 31 s.
After a diagnostic
command is set for
Sthe HDD, but the
device remains busy
for over 6 s.
A diagnostic command is
issued to the HDD device
but the result is an error
No response to the
self-diagnostic command
from the ASIC to the HDDs
Mandolin does not respond,
the HDD device remains
BUSY for more than 31 s,
or the BUSY signal does
not drop within 6 s after the
diagnostic command is
issued to the HDDs.
Error returned from HDD in
response to the
self-diagnostic command,
Mandolin could not be
located due to a read/write
error at the HDD register.
HDD defective
HDD harness disconnected,
defective
Controller board defective
HDD defective
HDD defective
HDD connector loose or defective
Controller defective
HDD defective
3-56