Service Program Mode Tables
IdlingTime (CapacitatorLowVoltage)
*For only C4c (DOM): [0 to 300 /90/1sec]
1105*
Fusing Temperature Adjustment
Adjusts the fusing temperature of the hot roller for plain paper, OHP or thick
paper.
Normal Time (Center
001
Thermistor)
Normal Time (End
002
Thermistors)
003 OHP (Center Thermistor)
004 OHP (End Thermistor)
Thick Paper (Center
005
Thermistor)
Thick Paper (End
006
Thermistors)
Normal Paper (Center
007
Thermistor)
Normal Paper (End
008
Thermistor)
D062/D063/D065/D066
Fusing temperature during the ready condition and
during printing.
D062/D063/D065: [180 to 205/190/1 degree C]
D066: [180 to 205/185/1 degree C]
Fusing temperature during the ready condition
D062/D063/D065: [150 to 205/190/1 degree C]
D066: [150 to 200/185/1 degree C]
Fusing temperature during printing:
D062/D063/D065: [150 to 205/190/1 degree C]
D066: [150 to 200/170/1 degree C]
Fusing temperature during printing:
D062/D063/D065: [150 to 205/190/1 degree C]
D066: [150 to 200/170/1 degree C]
Fusing temperature during printing:
D062/D063/D065: [180 to 205/200/1 degree C]
D066: [150 to 200/195/1 degree C]
Fusing temperature during printing:
D062/D063/D065: [180 to 205/200/1 degree C]
D066: [150 to 200/195/1 degree C]
Fusing temperature during printing:
D062/D063/D065: [150 to 230/190/1 degree C]
D066: [150 to 200/185/1 degree C]
Fusing temperature during printing:
D062/D063/D065: [150 to 205/190/1 degree C]
4-4