Ricoh D065 Service Manual page 449

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Service Call Conditions
1.
Check the SBU-SIOB/SIOB-BCU harness connections or replace these
harnesses.
2.
Replace the SBU.
3.
Replace the BCU
White level detection error
D
The white level cannot be adjusted to the second target level within the target
during auto gain control.
Dirty exposure lamp or optics section
SBU board defective
SIOB defective
IPU board defective
BCU board defective
Harnesses are disconnected.
142
Exposure lamp defective
Lamp stabilizer defective
-
Scanner motor defective
1.
Clean the exposure glass, white plate, mirrors, and lens.
2.
Check if the exposure lamp is lit during initialization.
3.
Check the harness connection.
4.
Replace the exposure lamp.
5.
Replace the scanner motor.
6.
Replace the SBU board, SIOB, IPU board or BCU board.
SBU auto gain error
C
The white level cannot be adjusted to the first target level within the target
during auto gain control.
143
SBU board defective
SIOB board defective
-
IPU board defective
BCU board defective
Scanner motor defective
D062/D063/D065/D066
3-4
SM Appendix

Advertisement

Table of Contents
loading

Table of Contents