Ricoh D065 Service Manual page 374

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Display
xx/xx
Download Error
02
E02 Power off/on
Download Error
03
E03 Power off/on
Download Error
04
E04 Power off/on
Download Error
05
E05 Power off/on
Download Error
06
E06
Power off/on
SM
Details
stored in NVRAM, the break module
information and the decompression
module capable of writing do not
match.
Controller ROM update error 2.
Error occurs during ROM update
program initialization.
Controller ROM update error 3
The ROM for the write operation
does not exist.
Controller ROM update error 4
GZIP data confirmation fails. (CRC
value check)
Controller ROM update error 5
Error occurs when writing to the
device.
Controller ROM update error 6
CPU clock error.
6-7
Program Download
Recovery
Turn the machine
off/on to rewrite
Turn the machine
off/on
Install the missing
ROM DIMM
Turn the machine
off/on
Set DIP SW 1 to
ON and retry
Replace RAM
DIMM
Replace controller
board
Turn the machine
off/on
Set DIP SW 1 to
ON and retry
Replace RAM
DIMM
Replace controller
board
Turn the machine
power off/on.
Set controller
DIPSW-1 to ON to
D062/D063/D065/D066

Advertisement

Table of Contents
loading

Table of Contents