Firmware Error Codes

Attention:
If you replace FRUs or perform an action and the problem is still not corrected, go to "MAP
1548: Processor Subsystem Problem Isolation" on page 139 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" in the RS/6000
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Table 4. Firmware Error Codes.
Error Code Description
20A8 0000 Insufficient information to boot.
20A8 0001 The client IP address is already in use by some
other network device.
20A8 0002 Cannot get gateway IP address.
20A8 0003 Cannot get system hardware address.
20A8 0004 Bootup failed.
20A8 0005 File transmission (TFTP) failed.
20A8 0006 Boot image too large
20D0 0001 I/O subsystem has changed locations
20D0 000F Self-test failed on a device, no error and/or
location code information available.
20D0 0010 Self-test failed on a device, cannot locate
package
20D0 0011 Firmware RTAS attempt to allocate memory
failed.
20D0 0800 Firmware update failure
20D0 0801 System firmware update failure
20D0 0997 Operating system terminated with error string
226
Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide
Action/
Possible Failing FRU
Verify the IP address.
Change IP address.
Refer to 168 using code E174.
Refer to 168 using code E174.
Refer to 168 using code E175.
Check network connection, try again.
Contact your next level of support for
assistance.
This is an informational message.
The I/O subsystem at the location code
associated with this message was found at
another location code during a prior boot of the
system.
If an I/O subsystem has not been moved, do
the following:
1. Boot the system and match the I/O
subsystem location codes reported by the
operating system to the subsystems
attached to the CEC. Check the SPCN and
RIO cabling to the I/O subsystems. If an
cabling problem is found, correct it.
2. If no cabling problem is found, call your
next level of support.
Refer to "Mapping AIX and Physical Location
Codes" on page 28 to see if a location code is
available for the device the error was reported
against.
1. Replace device indicated by the location
code (if available).
2. Go to "MAP 1542: I/O Problem Isolation" on
page 127
Contact your service support representative for
assistance.
Contact your next level of support for
assistance.
Retry the flash update.
Retry the firmware update.
Call service support.

Advertisement