Problem Determination Generated Error Codes

Table 6. Problem Determination Generated Error Codes
Error Code Description
M0BT 0000 The system hung during speaker POST. This
error code is generated by the customer
performing "Problem Determination" in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User's Guide.
M0BT 0001 The system hung during "Starting Software...".
This error code is generated by the customer
performing "Problem Determination" in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User's Guide.
M0KB D000 The system hung during keyboard POST. This
error code is generated by the customer
performing "Problem Determination" in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User's Guide.
M0KB D001 The system did not respond to a keyboard entry.
This error code is generated by the customer
performing "Problem Determination" in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User's Guide.
M0KB D002 The system did not respond to a keyboard entry.
This error code is generated by the customer
performing "Problem Determination" in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User's Guide.
M0KB D003 The system did not respond to a keyboard entry.
This error code is generated by the customer
performing "Problem Determination" in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User's Guide.
M0ME M002 The system hung during memory POST. This
error code is generated by the customer
performing "Problem Determination" in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User's Guide.
M0NE T000 The system hung during network POST. This
error code is generated by the customer
performing "Problem Determination" in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User's Guide.
M0PS 0000 Power failure. This error code is generated by
the customer performing "Problem
Determination" in the Eserver pSeries 630
Model 6C4 and Model 6E4 User's Guide.
M0SC SI00 Unable to load diagnostics. This error code is
generated by the customer performing "Problem
Determination" in the Eserver pSeries 630
Model 6C4 and Model 6E4 User's Guide.
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
1. Keyboard
2. CEC backplane
Location: U0.1-P1
Type 101 keyboard
1. Keyboard
2. CEC backplane
Location: U0.1-P1
Type 102 keyboard
1. Keyboard
2. CEC backplane
Location: U0.1-P1
1. Keyboard
2. CEC backplane
Location: U0.1-P1
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1520: Power" on page 105.
Go to "Boot Problems/Concerns" on page 204.
Chapter 5. Error Code to FRU Index