Table 4. Firmware Error Codes. (continued)
Error Code Description
20FF00C0 Invalid VPD (missing base address of the
RIO-PCI bridge)
20FF00D0 Invalid VPD (machine type field is invalid)
20FF00F0 Invalid VPD (the rack number and the unit
number are not found in the SCF partition in
NVRAM)
2100 0xxx SCSI controller fault
2101 0010 The IDE device remained busy longer than the
time-out period allows.
2101 0011 Execution of the command by the IDE CD-ROM
was not completed within the allowed time.
2101 0012 Execution of the ATA command by the IDE
CD-ROM failed.
2101 0013 Bootable media is missing from the IDE
CD-ROM.
2101 0014 The media in the IDE CD-ROM drive has been
changed.
2101 0015 Packed command execution by the IDE
CD-ROM failed.
Action/
Possible Failing FRU
1.
Replace the part specified by the location
code.
2. If no location code is shown with the error
code, call service support.
1.
Replace the part specified by the location
code.
2. If no location code is shown with the error
code, call service support.
1.
Replace the part specified by the location
code.
2. If no location code is shown with the error
code, call service support.
1. Before replacing any system components,
refer to the notes in error code 21A00001.
2. Replace the SCSI device.
1. Retry the operation.
2. Check for system firmware updates.
3. Call service support.
1. Retry the operation.
2. The CD in the IDE CD-ROM may not be
readable. Try another CD.
1. Check the power and signal connectors
going to the IDE CD-ROM.
2. Retry the operation.
3. The CD in the IDE CD-ROM may not be
readable. Try another CD.
Put a bootable CD in the IDE CD-ROM drive.
1. Retry the operation.
2. Check for system firmware updates.
3. Call service support.
1. The CD in the IDE CD-ROM may not be
readable. Try another CD.
2. Check for system firmware updates.
3. Call service support.