Service
Description and Action
Request
Number
A05-06x
Description: System shutdown due to abnormally high internal temperature. Action: Verify
that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then proceed with "MAP 1230: Linux Platform Error Problem
Resolution" on page 80.
A05-07x
Description: Sensor indicates a power supply has failed. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 80.
A05-08x
Description: System shutdown due to power supply failure. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 80.
A05-09x
Description: Sensor detected a FRU that has failed. Action: Use "MAP 1230: Linux Platform
Error Problem Resolution" on page 80.
A05-10x
Description: System shutdown due to FRU that has failed. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 80.
A05-14x
Description: System shutdown due to power fault with an unspecified cause. Action: Use
"MAP 1230: Linux Platform Error Problem Resolution" on page 80.
A05-16x
Description: System shutdown due to internal power supply failure. Action: Use "MAP 1230:
Linux Platform Error Problem Resolution" on page 80.
A05-19x
Description: System shutdown due to Fan failure. Action: Use "MAP 1230: Linux Platform
Error Problem Resolution" on page 80.
A05-21x
Description: System shutdown due to Over temperature condition. Action: Verify the
following:
v The room ambient temperature is within the system operating environment.
v There is unrestricted air flow around the system.
v All system covers are closed.
If all conditions are met, then use "MAP 1230: Linux Platform Error Problem Resolution" on
page 80.
A05-22x
Description: System shutdown due to over temperature and fan failure. Action: Use "MAP
1230: Linux Platform Error Problem Resolution" on page 80.
A05-24x
Description: Power Fault specifically due to internal battery failure. Action: Use "MAP 1230:
Linux Platform Error Problem Resolution" on page 80.
A0D-00x
Description: Error log analysis indicates an error detected by the Service Processor, but the
failure could not be isolated. Action: Use "MAP 1230: Linux Platform Error Problem
Resolution" on page 80.
A0D-01x
Note: Ensure that the system IPLROS and Service Processor are at the latest firmware
level before removing any parts from the system. Description: Time-out communication
response from Service Processor. Action: Use "MAP 1230: Linux Platform Error Problem
Resolution" on page 80.
A0D-02x
Description: I/O (I2C) general bus error.
Note: If you are servicing a 9076/Nxx system, go to the Service Processor Error Log (SVP).
Action: Use "MAP 1230: Linux Platform Error Problem Resolution" on page 80.
A0D-03x
Description: Secondary I/O (I2C) general bus error. Action: Use "MAP 1230: Linux Platform
Error Problem Resolution" on page 80.
A0D-04x
Description: Internal Service Processor memory error. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 80.
532
Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide