Checkpoint
E535
E536
E537
E538
E539
Description
Valid node ID detected at other end of the
RIO cable
I/O subsystem detected at other end of the
RIO cable
Configuring the I/O subsystem
Detected the RIO hub on the other end of
the RIO cable
Enabling the RIO hub ports
Action/
Possible Failing FRU
1. Replace the RIO-2 cable specified by
the location code.
2. Replace the RIO riser card that the
failing drawer is attached to.
3. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
4. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
5. Replace the I/O subsystem planar that
the RIO-2 cable in step 1 is attached to.
6. Go to "MAP 1540: Problem Isolation
Procedures" on page 124.
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 124.
1. Replace the RIO-2 cable specified by
the location code.
2. Replace the RIO riser card that the
failing drawer is attached to.
3. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
4. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
5. Replace the I/O subsystem planar that
the RIO-2 cable in step 1 is attached to.
6. Go to "MAP 1540: Problem Isolation
Procedures" on page 124.
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 124.
1. Check for system firmware updates.
2. Replace the RIO riser card specified by
the location code.
3. Go to "MAP 1540: Problem Isolation
Procedures" on page 124.
Chapter 4. Checkpoints
181