IBM pSeries 630 6C4 Service Manual page 199

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

Checkpoint
E52B
E52F
E530
E531
Description
The RIO cable connected to the RIO port
has been detected
End of configuration of the RIO hub
Checking RIO hub ports on current RIO
hub
Get RIO hub node ID
Action/
Possible Failing FRU
1. Check the RIO cable specified by the
location code. If the location code
specifies an I/O subsystem or its RIO
interface, check the RIO cables going
into and out of the I/O subsystem.
2. Verify that the entire RIO loop
associated with the location code is
cabled correctly.
3. Replace the RIO cables specified by
the location code. If the location code
specifies an I/O subsystem or its RIO
interface, replace the RIO cables going
into and out of the I/O subsystem.
4. Replace the RIO riser, U0.dd-P1.1, in
the I/O drawer that the RIO cables in
step 1 are attached to.
5.
Replace the CEC backplane, U0.1-P1.
6. Go to "MAP 1542: I/O Problem
Isolation" on page 127.
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 124.
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 124.
1. Replace the RIO-2 cable specified by
the location code.
2. Replace the RIO riser card that the
failing drawer is attached to.
3. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
4. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
5. Replace the I/O subsystem planar that
the RIO-2 cable in step 1 is attached to.
6. Go to "MAP 1540: Problem Isolation
Procedures" on page 124.
Chapter 4. Checkpoints
179

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pseries 630 6e4

Table of Contents