Step 1548-18
Look at the FRU part numbers associated with the SRN.
Have you exchanged all the FRUs that correspond to the failing function codes (FFCs)?
NO
Exchange the FRU with the highest failure percentage that has not been changed.
Repeat this step until all the FRUs associated with the SRN have been exchanged or diagnostics
run with no trouble found. Run diagnostics after each FRU is exchanged.
If the CEC backplane or a network adapter is removed, see notes on page 61.
Go to "MAP 0410: Repair Checkout" in the RS/6000 Eserver pSeries Diagnostic Information for
Multiple Bus Systems.
YES
If the symptom did not change and all the FRUs have been exchanged, call service support for
assistance.
Step 1548-19
Does the system have adapters or devices that require supplemental media?
NO
Go to "Step 1548-20".
YES
Go to "Step 1548-21".
Step 1548-20
Consult the PCI adapter configuration documentation for your operating system to verify that all installed
adapters are configured correctly.
Go to "MAP 0410: Repair Checkout" in the RS/6000 Eserver pSeries Diagnostic Information for Multiple
Bus Systems.
If the symptom did not change and all the FRUs have been exchanged, call service support for assistance.
Step 1548-21
1. Select Task Selection.
2. Select Process Supplemental Media and follow the onscreen instructions to process the media.
Supplemental media must be loaded and processed one at a time.
Did the system return to the TASKS SELECTION SCREEN after the supplemental media was
processed?
NO
Go to "Step 1548-22" on page 151.
YES
Press F3 to return to the FUNCTION SELECTION screen.
Go to "Step 1548-17" on page 149, substep 4.