Bring-Up Phase - IBM pSeries 630 6C4 Service Manual

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

The standby phase components are as follows:
v Modem Configuration
The service processor configures the modem (if installed) so that incoming calls can be received, or
outgoing calls can be placed.
v Dial In
Monitor incoming phone line to answer calls, prompt for a password, verify the password, and remotely
display the standby menu. The remote session can be mirrored on the local HMC virtual terminal
window if the system is so equipped and if the user enables this function.
v Menus
The service processor menus are password-protected. Before you can access them, you need either
the general user-password or privileged-user password.
Service processor menus are available on ASCII terminals attached to the serial ports on the system,
and on terminal emulators. On HMC-managed systems, service processor menus are also available on
the HMC interface.

Bring-Up Phase

On a system that is powered-on to full system partition, this phase is entered upon power-on, and exited
upon loading of the operating system.
On a system that is powered-on to partition standby, this phase is entered upon power-on, and exited
when the partition manager and hypervisor have been loaded and become fully operational in system
memory. The end of this phase is indicated by LPAR on the operator panel. At this point, the server can
start multiple logical partitions that would be activated through the HMC interface.
The bring-up phase components are as follows:
v Retry Request Check
The service processor checks to see if the previous boot attempt failed. If the specified number of
failures are detected, the service processor displays an error code and places an outgoing call to notify
an external party if the user has enabled this option.
v Dial Out
The service processor can dial a preprogrammed telephone number in the event of an IPL failure. The
service processor issues an error report with the last reported IPL status indicated and any other
available error information.
v Update Operator Panel
The service processor displays operator panel data on the HMC virtual terminal window if a remote
connection is active.
v Environmental Monitoring
The service processor provides expanded error recording and reporting.
v System Firmware Surveillance (Heartbeat Monitoring)
The service processor monitors and times the interval between system firmware heartbeats.
v Responding to System Processor Commands
The service processor responds to any command issued by the system processor.
Chapter 7. Using the Service Processor