Table 5. Service Processor Error Codes. (continued)
Error Code Description
4067 0EB6 Attention line 5 stuck fault
4067 0EB7 Attention line 6 stuck fault
4067 0EB8 Attention line 7 stuck fault
4067 0EB9 Attention line 8 stuck fault
4067 0EBA Attention line 9 stuck fault
4067 0EBB Attention line 10 stuck fault
4067 0EBC Attention line 11 stuck fault
4067 0EBF Description: Memory error
Action:
1. Reboot the system in slow mode to the SMS menus. See "Performing Slow Boot" on page 209.
2. Examine the service processor error log.
v If a CEC subsystem error (a 4xxx yyyy error) occurred during the slow boot that calls out the
memory, processors, L3 cache modules or the primary I/O book, replace the part indicated
by the location code.
v If a CEC subsystem error (a 4xxx yyyy error) did not occur during the slow boot, look for a
4xxx yyyy error immediately preceding the 4067 0EBF error. Replace the part indicated by
the location code associated with that error.
4067 0EE1 Service processor firmware: invalid MRU to FRU
mapping
4067 0EE2 Service processor firmware fault
4067 0EE5 Firmware error, no callout available
4068 0001 Scan interface basic assurance tests detected a
CEC backplane fault
4068 0002 CEC backplane fault
4068 0003 Scan interface basic assurance tests detected
processor fault
4068 0004 Processor fault
4068 000E Processor capacity card
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
CEC backplane
Location: U0.1-P1
1. Check JTAG cable connections
2. CEC backplane
Location: U0.1-P1
1. Check JTAG cable connections.
2. Processor card
Location: U0.1-P1-C1
1. Check JTAG cable connections.
2. Processor card
Location: U0.1-P1-C2
Operator Panel
Location: U0.1-L1