IBM pSeries 630 6C4 Service Manual page 55

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

2. On the AIX command line, type lsslot -c pci |pg
This list relates the AIX logical name of all resources to location code. Look for the AIX logical name
that you recorded in the first step and read the location code of the resource. You can then determine
the physical location of the resource by flashing the FRU identify LED (see "FRU Identify LEDs" on
page 27) that corresponds to the location code.
FRU Name
Model D20 I/O Drawer U0.dd (dd = any number from 2 through 63)
Rack frame
I/O drawer backplane
I/O subsystem drawer
RIO bus adapter
RIO port 1 upper connector
RIO port 1 cable
RIO port 0 lower connector
RIO port 0 cable
PCI bus controller PHB0
PCI to PCI bridge EADS-X
PCI bus controller PHB2
PCI to PCI bridge (EADS_X)
PCI slot 1
PCI card in slot 1
PCI slot 2
PCI card in slot 2
PCI slot 3
PCI card in slot 3
PCI slot 4
PCI card in slot 4
PCI slot 5
PCI card in slot 5
PCI slot 6
PCI card in slot 6
PCI slot 7
PCI card in slot 7
Power supply 1 (no internal blower)
Power supply 2 (no internal blower)
Physical Location Code
First I/O Subsystem Location Codes
U0
U0.dd-P1
U0.dd
RIO Bus Adapter
U0.dd-P1.1
U0.dd-P1.1/Q1
U0.dd-P1.1/Q1#
U0.dd-P1.1/Q2
U0.dd-P1.1/Q2#
PCI Bus Controller
U0.dd-P1
U0.dd-P1
PCI Bus Controller PHB2
U0.dd-P1
U0.dd-P1
Pluggable Adapter Slots
U0.dd-P1/I1
U0.dd-P1-I1
U0.dd-P1/I2
U0.dd-P1-I2
U0.dd-P1/I3
U0.dd-P1-I3
U0.dd-P1/I4
U0.dd-P1-I4
U0.dd-P1/I5
U0.dd-P1/I5
U0.dd-P1/I6
U0.dd-P1/I6
U0.dd-P1/I7
U0.dd-P1/I7
Power Supply
U0.dd-V1
U0.dd-V2
Cooling Blowers
AIX Location Code
1r-10, 1r-12, 1r-16
2Q-10, 2Q-12, 2Q-14, 2Q-16
2R-08
2U-08
2a-08
2d-08
1s-08
1v-08
25–08
Chapter 1. Reference Information
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pseries 630 6e4

Table of Contents