IBM pSeries 630 6C4 Service Manual page 217

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

Checkpoint
E591
E592
E593
E594
Description
Set up EADS function registers
Set up EADS function registers
Set up EADS function registers
Begin probing slots
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Replace the I/O subsystem's RIO riser
card (location: U0.dd-P1.1) specified by
the location code.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
4. Replace the I/O subsystem backplane
specified by the location code.
5. Go to "MAP 1542: I/O Problem
Isolation" on page 127.
1. Check for system firmware updates.
2. Replace the I/O subsystem's RIO riser
card (location: U0.dd-P1.1) specified by
the location code.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
4. Replace the I/O subsystem backplane
specified by the location code.
5. Go to "MAP 1542: I/O Problem
Isolation" on page 127.
1. Check for system firmware updates.
2. Replace the I/O subsystem's RIO riser
card (location: U0.dd-P1.1) specified by
the location code.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
4. Replace the I/O subsystem backplane
specified by the location code.
5. Go to "MAP 1542: I/O Problem
Isolation" on page 127.
1. Check for system firmware updates.
2. Replace the I/O subsystem's RIO riser
card (location: U0.dd-P1.1) specified by
the location code.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
4. Replace the I/O subsystem backplane
specified by the location code.
5. Go to "MAP 1542: I/O Problem
Isolation" on page 127.
Chapter 4. Checkpoints
197