Fip Snooping In A Switch Stack; Using Fip Snooping; Fip Snooping Prerequisites - Dell S6000–ON Configuration Manual

Hide thumbs Also See for S6000–ON:
Table of Contents

Advertisement

To provide more port security on ports that are directly connected to an FCF and have links to other
FIP snooping bridges, set the FCF or Bridge-to-Bridge Port modes.
To ensure that they are operationally active, check FIP snooping-enabled VLANs.
Process FIP VLAN discovery requests and responses, advertisements, solicitations, FLOGI/FDISC
requests and responses, FLOGO requests and responses, keep-alive packets, and clear virtual-link
messages.

FIP Snooping in a Switch Stack

FIP snooping supports switch stacking as follows:
A switch stack configuration is synchronized with the standby stack unit.
Dynamic population of the FCoE database (ENode, Session, and FCF tables) is synchronized with the
standby stack unit. The FCoE database is maintained by snooping FIP keep-alive messages.
In case of a failover, the new master switch starts the required timers for the FCoE database tables.
Timers run only on the master stack unit.

Using FIP Snooping

There are four steps to configure FCoE transit.
1.
Enable the FCoE transit feature on a switch.
2.
Enable FIP snooping globally on all Virtual Local Area Networks (VLANs) or individual VLANs on a FIP
snooping bridge.
3.
Configure the FC-Map value applied globally by the switch on all VLANs or an individual VLAN.
4.
Configure FCF mode for a FIP snooping bridge-to-FCF link.
For a sample FIP snooping configuration, refer to
Statistical information is available for FIP Snooping-related information. For available commands, refer to
the FCoE Transit chapter in the Dell Networking OS Command Line Reference Guide.

FIP Snooping Prerequisites

Before you enable FCoE transit and configure FIP snooping on a switch, ensure that certain conditions
are met.
A FIP snooping bridge requires data center bridging exchange protocol (DCBx) and priority-based flow
control (PFC) to be enabled on the switch for lossless Ethernet connections (refer to the
Bridging (DCB)
chapter). Dell Networking recommends also enabling enhanced transmission selection
(ETS); however, ETS is recommended but not required.
If you enable DCBx and PFC mode is on (PFC is operationally up) in a port configuration, FIP snooping is
operational on the port. If the PFC parameters in a DCBx exchange with a peer are not synchronized, FIP
and FCoE frames are dropped on the port after you enable the FIP snooping feature.
For VLAN membership, you must:
create the VLANs on the switch which handles FCoE traffic (use the interface vlan command).
configure each FIP snooping port to operate in Hybrid mode so that it accepts both tagged and
untagged VLAN frames (use the portmode hybrid command).
FCoE Transit
FIP Snooping Configuration
Example.
Data Center
317

Advertisement

Table of Contents
loading

Table of Contents