Dell S6000–ON Configuration Manual page 949

Hide thumbs Also See for S6000–ON:
Table of Contents

Advertisement

2.
Configure the VLT peer link port channel id in VLT peer 1 and VLT peer 2.
3.
In the Top of Rack unit, configure LACP in the physical ports (shown for VLT peer 1 only. Repeat
steps for VLT peer 2. The bold vlt-peer-lag port-channel 2 indicates that port-channel 2 is
the port-channel id configured in VLT peer 2).
Dell-2#show running-config interface tengigabitethernet 1/4/1
!
interface TenGigabitEthernet 1/4/1
no ip address
!
port-channel-protocol LACP
port-channel 2 mode active
no shutdown
configuring VLT peer lag in VLT
Dell-2#show running-config interface port-channel 2
!
interface Port-channel 2
no ip address
switchport
vlt-peer-lag port-channel 2
no shutdown
Dell-2#show interfaces port-channel 2 brief
Codes: L - LACP Port-channel
LAG
Mode
Status
L
2
L2L3
up
In the ToR unit, configure LACP on the physical ports.
s60-1#show running-config interface tengigabitethernet 1/8/1
!
interface TenGigabitEthernet 1/8/1
no ip address
!
port-channel-protocol LACP
port-channel 100 mode active
no shutdown
s60-1#show running-config interface tengigabitethernet 1/30/1
!
interface TenGigabitEthernet 1/30/1
no ip address
!
port-channel-protocol LACP
port-channel 100 mode active
no shutdown
s60-1#show running-config interface port-channel 100
!
interface Port-channel 100
no ip address
switchport
no shutdown
s60-1#show interfaces port-channel 100 brief
Codes: L - LACP Port-channel
LAG
Mode
Status
L
100
L2
up
Virtual Link Trunking (VLT)
Uptime
Ports
03:33:14
Te 1/4/1 (Up)
Uptime
Ports
03:33:48
Te 1/8/1 (Up)
Te 1/30/1 (Up)
949

Advertisement

Table of Contents
loading

Table of Contents