Media Settings (Continued)
Setting
Start Adjust
Stop Adjust
Media Calibration
Mode
Length (Slow Mode) If Media Calibration Mode is set to Slow, the printer
LTS Sensitivity
Level
Power Up Action
Head Down Action Sets the action when you close the print mechanism
PM23c, PM43, and PM43c Mid-Range Printer User Manual
Description
Sets the length of media the printer feeds (positive
value) or retracts (negative value) before printing a
label. Unit of measurement is defined in the Unit of
Measure parameter. Range is -9999 to +9999.
Sets the length of media the printer feeds (positive
value) or retracts (negative value) after printing a label.
Unit of measurement is defined in the Unit of Measure
parameter. Range is -9999 to +9999.
Selects the mode the printer uses to calibrate media.
Use Slow if the printer has trouble identifying gaps or
marks in media.
prints the media length plus 10 mm. This value sets an
additional amount of media to be printed. Unit of
measurement is defined in the Unit of Measurement
parameter. Range is 0 to 3200.
Sets the sensitivity of the label taken sensor. Range is 0
to 14. Supported when the Cutter or Label Dispenser
accessories are installed.
Sets the action when you turn the printer on:
No Action
Formfeed - The printer feeds one label.
Testfeed - The printer prints two configuration
labels as it calibrates the media sensors.
after opening it:
No Action
Formfeed - The printer feeds one label.
Testfeed - The printer prints two configuration
labels as it calibrates the media sensors.
Appendix B — Default Settings
Default
0
0
Fast
0
0
No Action
No Action
139