4.18 [2-10] Extension CID Settings
Feature Manual References
3.1.1 Caller ID
Channel Seizure Signal Bits
Specifies the number of seizure bits to send when sending Caller ID information to an SLT.
Default
300 bits
Value Range
10 ´ n (n=3–40) bits
Maintenance Console Location
4.18 [2-10] Extension CID Settings
Programming Manual References
None
Feature Manual References
3.1.1 Caller ID
Mark Signal Bits
Specifies the number of mark bits to send when sending Caller ID information to an SLT.
Default
180 bits
Value Range
10 ´ n (n=3–40) bits
Maintenance Console Location
4.18 [2-10] Extension CID Settings
Programming Manual References
None
Feature Manual References
3.1.1 Caller ID
Channel Seizure Wait Time
Specifies the length of time that the PBX waits before starting to send the seizure signal following the first ring
when sending Caller ID information to an SLT.