Feature Manual References
None
Port Status
Indicates the port status of the mounted option card (reference only).
Default
Current port status
Value Range
INS: The card is in service.
OUS: The card is out of service.
Fault: The card is pulled out from the sub-slot, or is not communicating with the PBX.
Maintenance Console Location
3.27 [1-1] Slot—OPB3 Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Input Signal Decision Time
Specifies the minimum duration of continuous input from the triggered sensor before the PBX recognizes the
input and makes a sensor call.
Default
1024 ms
Value Range
32 ´ n (n=2–255) ms
Maintenance Console Location
3.27 [1-1] Slot—OPB3 Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
5.1.9 External Sensor
Document Version 2008-11
3.27 [1-1] Slot—OPB3 Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
PC Programming Manual
211