4.4 [2-3] Timers & Counters
Feature Manual References
5.1.9 External Sensor
Incoming Call Inter-digit Timer—DID
Specifies the length of time between digits when receiving a DID number from a public network. The call will
be redirected to a PBX operator when this timer expires.
Default
10 s
Value Range
0–30 s
Maintenance Console Location
4.4 [2-3] Timers & Counters
Programming Manual References
12.3 [10-3] DID Table
Feature Manual References
4.1.5 DID (Direct Inward Dialing)
Incoming Call Inter-digit Timer—TIE
Specifies the length of time between digits when receiving a dialed number from a TIE line. The call will be
redirected to a PBX operator when this timer expires.
Default
10 s
Value Range
3–30 s
Maintenance Console Location
4.4 [2-3] Timers & Counters
Programming Manual References
11.1 [9-1] TIE Table
Feature Manual References
13.1.13 PRIVATE NETWORK FEATURES