Network Type - Panasonic KX-TDA200 Programming Manual

Hide thumbs Also See for KX-TDA200:
Table of Contents

Advertisement

Select the desired cell in the column, and then click Command.
Default
Current status
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Maintenance Console Location
3.14 [1-1] Slot—Port Property - PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
3.15 [1-1] Slot—Port Property - PRI Port—Connection Command (KX-TDA100/KX-TDA200/KX-TDA600 only)
Feature Manual References
None

Network Type

Selects the network type of the port.
Default
51 US National ISDN 2
Value Range
0–56
(2 UK (Domestic), 5 Netherlands, 6 SwissNET2, 7 SwissNET3, 8 Euro ISDN (Standard), 14 France
(Domestic), 19 Finland, 20 Norway, 27 Australia, 51 US National ISDN 2)
Maintenance Console Location
3.14 [1-1] Slot—Port Property - PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
9.1.16 ISDN (INTEGRATED SERVICES DIGITAL NETWORK) FEATURES
Network Numbering Plan
Shelf (KX-TDA600 only)
Indicates the shelf position (reference only).