2KN/2KP
Maintenance
item No.
Setting the other high voltages
U101
Description
Sets the developing bias control voltage, the transfer control voltage, and the reverse transfer bias control
voltage or checks the output of these voltages.
Purpose
To check or change the developing bias, the transfer voltage, and the reverse transfer bias voltage.
Method
Press the start key. The screen for selecting an item is displayed.
Display
DEV BIAS SET
TC SET
TC REV SET
VPP SET
PTC TEST
Setting
1. Select the item to be set.
2. Change the setting using the * or # keys.
3. Press the start key. The value is set.
PTC section operation check
1. Select PTC TEST at the screen for selecting an item.
2. Press the start key.
Drive motor, transfer motor and developing motor are turned on, and then cleaning lamp and PTC unit is
turned on.
Supplement
While this maintenance item is being executed, copying from an original is available in the interrupt copying
mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for maintenance item No. is dis-
played.
1-3-42
Description
Description
Developing bias control voltage
Transfer control voltage
Reverse transfer control voltage
VPP setting value
PTC section operation check
Setting
Default
range
setting
0 to 255
117
0 to 255
185 (82 cpm)
135 (62 cpm)
0 to 255
215
60 to 196
145
-
-