Kyocera TASKalfa 620 Service Manual page 379

Hide thumbs Also See for TASKalfa 620:
Table of Contents

Advertisement

Connector
Pin No.
YC23
1
Connected
2
to the devel-
3
oping
humidity
4
sensor
YC24
1
Connected
2
to the cool-
ing fan
motors 1/2/
3
4, PWB fan
4
motor 1/2,
scanner fan
motor, LSU
fan motor
5
and devel-
6
oping duct
fan motor
7
8
9
10
11
12
13
14
15
16
Signal
I/O
D TEMP SENS
I
GND
-
D HUMID
I
SENS
5V
O
GND
-
COOL FAN 1
O
REM
GND
-
COOL FAN 2
O
REM
GND
-
COOL FAN 4
O
REM
GND
-
PCB FAN 1
O
REM
GND
-
PCB FAN 2
O
REM
GND
-
SCANNER FAN
O
REM
GND
-
LSU FAN REM
O
GND
-
DLP FAN R
O
REM
Voltage
Analog
Developing humidity sensor temperature detec-
tion signal
-
Ground
Analog
Developing humidity sensor humidity detection
signal
5 V DC
5 V DC power output
-
Ground
24 to 20.92/
Cooling fan motor 1: full speed/half speed/off
20.92 to 0.5/
0.5 to 0 V DC
-
Ground
24 to 20.92/
Cooling fan motor 2: full speed/half speed/off
20.92 to 0.5/
0.5 to 0 V DC
-
Ground
0/24 V DC
Cooling fan motor 4: On/off
-
Ground
24 to 20.92/
PWB fan motor 1: full speed/half speed/off
20.92 to 0.5/
0.5 to 0 V DC
-
Ground
24 to 20.92/
PWB fan motor 2: full speed/half speed/off
20.92 to 0.5/
0.5 to 0 V DC
-
Ground
0/12/24 V DC
Scanner fan motor: full speed/half speed/off
-
Ground
0/12/24 V DC
LSU fan motor: full speed/half speed/off
-
Ground
0/24 V DC
Developing duct fan motor: On/off
2KN/2KP
Description
2-3-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 820

Table of Contents