Kyocera TASKalfa 620 Service Manual page 116

Hide thumbs Also See for TASKalfa 620:
Table of Contents

Advertisement

2KN/2KP
Maintenance
item No.
Setting the low-power mode
U344
Description
Changes the control for low-power mode.
Purpose
According to user request, selects which has priority, the recovery time from low-power or energy saver.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select control mode. The selected item is displayed in reverse.
Display
ENERGY STAR
GEEA
Initial setting: ENERGY STAR (120 V specifications)/GEEA (220-240 V specifications)
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
Press the stop/clear key at the screen for selecting an item.
The screen for selecting a maintenance item No. is displayed.
Setting the value for maintenance due indication
U345
Description
Sets when to display a message notifying that the time for maintenance is about to be reached, by setting the
number of copies that can be made before the current maintenance cycle ends.
When the difference between the number of copies of the maintenance cycle and that of the maintenance
count reaches the set value, the message is displayed.
This maintenance mode is effective for only Japanese specification.
1-3-78
Description
Description
The fuser control temperature is as low-power mode control temper-
ature and forced stabilization is performed 10 seconds after exiting
preheat.
The fuser control temperature is as low-power mode control temper-
ature and forced stabilization is performed 10 seconds after exiting
preheat.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 820

Table of Contents