2KN/2KP
Section
Jam code
Paper feed
21
section
23
24
25
26
27
Paper con-
28
veying sec-
tion
* Description in ( ) is written for the specified time of less then A4/11" x 8
1-4-4
Description
Misfeed in copier vertical
paper conveying section 4
Misfeed in deck paper
conveying section 2
Multiple sheets in cassette
paper feed section 1
Multiple sheets in cassette
paper feed section 2
Multiple sheets in cassette
paper feed section 3
Multiple sheets in cassette
paper feed section 4
Multiple sheets in deck
paper feed section 1
Feed switch 2 (FSW2) does not turn on within 600 ms of deck
convaying switch 1 (DKCSW1) turning on.
Feed switch 2 (FSW2) does not turn on within specified time
(1591 ms for 82 cpm/2047 ms for 62 cpm) of feed switch 4
(FSW4) turning on.
Feed switch 2 (FSW2) does not turn on within specified time
(2045 ms for 82 cpm/2632 ms for 62 cpm) of feed switch 5
(FSW5) turning on.
Deck conveying switch 1 (DKCSW1) does not turn on within
300 ms of deck conveying switch 2 (DKCSW2) turning on.
Deck conveying switch 2 (DKCSW2) does not turn on within
480 ms of timing switch 2 (TIMSW2) turning on.
Timing switch 4 (TIMSW4) does not turn off within specified
time <2000 ms (720 ms) for 82 cpm/2500 ms (720 ms) for 62
cpm> of its turning on.
Feed switch 5 (FSW5) does not turn off within specified time
<550 ms (400 ms) for 82 cpm/650 ms (400 ms) for 62 cpm> of
timing switch 4 (TIMSW4) turning on.
Timing switch 3 (TIMSW3) does not turn off within specified
time <2000 ms (720 ms) for 82 cpm/2500 ms (720 ms) for 62
cpm> of its turning on.
Feed switch 4 (FSW4) does not turn off within specified time
<550 ms (400 ms) for 82 cpm/650 ms (400 ms) for 62 cpm> of
timing switch 3 (TIMSW3) turning on.
Feed switch 4 (FSW4) does not turn off within specified time
<550 ms (400 ms) for 82 cpm/650 ms (400 ms) for 62 cpm> of
feed switch 5 (FSW5) turning off.
Feed switch 3 (FSW3) does not turn off within specified time
<550 ms (400 ms) for 82 cpm/650 ms (400 ms) for 62 cpm> of
feed switch 4 (FSW4) turning off.
Feed switch 2 (FSW2) does not turn off within specified time
(2045 ms for 82 cpm/2632 ms for 62 cpm) of timing switch 2
(TIMSW2) turning on.
Feed switch 2 (FSW2) does not turn off within specified time
(1591 ms for 82 cpm/2047 ms for 62 cpm) of timing switch 3
(TIMSW3) turning on.
Feed switch 2 (FSW2) does not turn off within specified time
(2045 ms for 82 cpm/2632 ms for 62 cpm) of timing switch 4
(TIMSW4) turning on.
Feed switch 2 (FSW2) does not turn off within specified time
(1891 ms for 82 cpm/2433 ms for 62 cpm) of its turning on.
Feed switch 2 (FSW2) does not turn off within 1340 ms of its
turning on.
Feed switch 2 (FSW2) does not turn off within 670 ms of deck
conveying switch 1 (DKCSW1) turning off.
Timing switch 2 (TIMSW2) does not turn off within 1340 ms of
its turning on.
Deck conveying switch 2 (DKCSW2) does not turn off within
550 ms of timing switch 2 (TIMSW2) turning off.
" size.