2KN/2KP
Maintenance
item No.
Setting OEM purchaser code
U265
Description
Sets the OEM purchaser code.
Purpose
Sets the code when replacing the main PWB and the like.
Or sets the data after executing U020 (Initializing all data).
Method
Press the start key.
Setting
1. Adjust the preset value using the cursor up/down keys.
2. Press the start key. The count is set, and the screen for selecting a maintenance item is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Setting the number of days after which to automatically delete documents
U266
Description
Sets the number of days to save documents on the HDD before automatically deleting.
Purpose
To change the number of days to retain data that is saved within the auto-delete area of the HDD before auto-
matically deleting.
Method
Press the start key. The current setting is displayed.
Setting
1. Change the setting using the cursor up/down keys.
Description
Number of days after which to automatically delete documents
2. Press the start key. The value is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Setting auto application change time
U277
Description
Sets the time that passes until the machine starts automatically printing after completing copying or operation
when the machine is used as a printer (only if the printer kit is installed).
Purpose
According to user request, changes the setting.
Method
Press the start key. The current setting is displayed.
Setting
1. Change the setting using the cursor up/down keys.
Description
Switching time
The setting can be changed by 30 s per step.
2. Press the start key. The value is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
1-3-72
Description
Setting range
30 to 270 (s)
Setting range Initial setting
0 to 7
0
Initial setting
30 (s)