2KN/2KP
Maintenance
item No.
Initializing the scanner NIC
U504
Description
Initializing the optional scanner NIC to its factory default.
Purpose
To return to a setup at the time of factory shipments.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel. It is displayed in reverse.
3. Press the start key. All data in the scanner NIC is initialized.
Completion
To exit this maintenance item without executing initialization, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Setting data base assistant
U505
Description
Sets whether or not the database linkage setting is enabled if an optional network scanner is installed.
Purpose
According to user request, changes the setting.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Display
ON
OFF
Initial setting: ON
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Setting the time out
U506
Description
Sets the communication timeout time for connection to a computer.
Purpose
To change the preset value if a communication error occurs after connection to a computer continues for a
long time. By delaying the error detection timing, the error may be cleared. If the error is not cleared after the
preset value is changed, however, return the preset value to the initial value.
Method
Press the start key. The current setting is displayed.
Setting
1. Change the value using the cursor up/down keys.
Description
Timeout time
The setting can be changed by 10 s per step.
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
1-3-84
Description
Description
Database linkage setting is enabled.
Database linkage setting is disabled.
Setting range
10 to 120 (s)
Initial setting
10