Enable; Disable; Set Autorevert - Symbol WS5000 Series System Reference Manual

Hide thumbs Also See for WS5000 Series:
Table of Contents

Advertisement

8.46.1 enable

Standby Context
Adds the switch to the Standby system.
Syntax
enable
Parameters
None.
Example
WS5000.(Cfg).standby> enable

8.46.2 disable

Standby Context
Removes the switch from the Standby system.
Syntax
disable
Parameters
None.
Example
WS5000.(Cfg).standby> disable

8.46.3 set autorevert

Standby Context
Enables or disables the automatic reversion feature. When auto-revert is enabled, a Standby switch that has
become active due to a failover automatically reverts to its monitoring role after the Primary switch comes back
up. If you disable auto-revert, you can manually revert the Standby switch through the revert option of the
mode
command.
"Auto-revert delay." If auto-revert is enabled, this is the amount of time to wait, in minutes, before the Primary
switch becomes active after it has come back up.
Note Be sure to call the
Syntax
set autorevert <enable_flag>
Parameters
enable_flag
Enable of disable auto-revert, as applicable.
Example
WS5000.(Cfg).standby> set autorevert enable
disable
command before calling this command.