Logging - Polycom SoundPoint IP 200W Provisioning And Configuration Manual

Hide thumbs Also See for SoundPoint IP 200W:
Table of Contents

Advertisement

Code: Description
10 : Unknown format of DirFile
11 : Server name lookup failed
12 : Authentication failed

Logging

Viewing Logs Using the Local Web Management
SoundPoint IP 200W phone will log various events to its local web
management logging folder.
To view logs using the local web management:
1. Using your default web browser, connect to:
http://<IP address of the gateway>
2. Log in using the default username and password.
For example, the default username and password is "Polycom" and "456".
3. Select Debuging.
Saving Logs on the Boot Server
SoundPoint IP 200W phone can copy its log to the boot server.
To copy a log to the boot server:
1. Verify that the <Boot Server>/Log directory was created on the boot
server.
2. Do one of the following steps:
Use configuration file to enable only boot logging (copies only the first
a
5K of boot log).
%VOIP_LOG_AUTO_UPLOAD%:1
Troubleshooting Your SoundPoint IP 200W Phones
Interpretation
The downloaded DirFile is in an unknown format. This
could indicate that the SoundPoint IP 200W is
downloading firmware from a wrong folder on the
firmware update server.
The DNS server cannot determine the IP address for
the provided firmware update server.
The HTTP request for the DirFile or firmware files failed
with a HTTP/1.1 401 response code. This indicates that
either the username or password is incorrect.
4 - 3

Advertisement

Table of Contents
loading

Table of Contents