Setting Alarm Activation Level; Installing The Translation File - Avaya S8500 Installing And Configuring

Hide thumbs Also See for S8500:
Table of Contents

Advertisement

Translating the IPSIs

Setting alarm activation level

These steps set the alarm activation level.
1. Type change system-parameters maintenance and press Enter.
change system-parameters maintenance
OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Update LSPs When Saving Translations: y
2. In the CPE Alarm Activation Level field, select none (default), warning, minor, or
major, depending on the level the customer wants and press Enter to effect the changes.
3. Repeat for each IPSI.

Installing the translation file

This step installs the translation file.
1. Type save translation and press Enter to save the translations to the hard drive.
64 Installing and Configuring the Avaya S8500 Media Server
MAINTENANCE-RELATED SYSTEM PARAMETERS
Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no
System Clocks/IPSI Interchange: no
Start Time: 22 : 00
Stop Time: 06 : 00