Enabling Ipsi Duplication (Duplicated Control Network Only); Setting The Alarm Activation Level; Saving Translations - Avaya S8730 Installing And Configuring

Hide thumbs Also See for S8730:
Table of Contents

Advertisement

4. Verify that all the other fields are populated and submit the form to save the changes.
5. Repeat this procedure for each port network.
Enabling IPSI duplication (duplicated control network
only)
Port networks with duplicated IPSIs have both primary (CNA) and secondary (CNB) IPSI circuit
packs. If you disable IPSI duplication, all primary IPSI circuit packs must be active.
Use the System-Parameters Duplication SAT screen to enable IPSI duplication.
1. Enter change system-parameters duplication.
2. Enter y in the Enable Operation of IPSI Duplication field.
3. Submit the screen to save the changes.

Setting the alarm activation level

1. At the SAT, type change system-parameters maintenance and press Enter.
2. In the CPE Alarm Activation Level field, enter none, warning, minor, or major,
according to the customer request.
3. Submit the screen to save the changes.
4. Repeat this procedure for each IPSI.

Saving translations

To save the translations to the hard disk drive, at the SAT, type save translation and press
Enter.
Installing and Configuring the Avaya S8700-Series Server

Enabling IPSI duplication (duplicated control network only)

55
January 2008

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8710S8700 seriesS8720

Table of Contents