Table 16. Error messages (continued)
Message
099 FORMS JAMMED
CLEAR JAM THEN PRESS START
(All paper paths)
201 NO ATTACHMENT CARD FOUND
SEE USER'S GUIDE
202 NEW ATTACHMENT CARD FOUND
DIAGNOSTIC IN PROGRESS
PLEASE WAIT (flashing)
SEE USER'S GUIDE
Description
Path sensor sensed paper still present
after attempted Park or Eject. For fanfold
forms, this message can display if you park
but do not tear off the output.
Path sensor detected forms already
present when you tried to load forms into a
fanfold path.
A serial, LAN, coax, or twinax attachment
card was not found during the current
power on, but was previously.
A new type of attachment card was found
during the current power on. This will occur
on the first power-on following the
installation of a new card.
Action
1. Ensure fanfold forms are torn off before
parking the forms.
2. Ensure fanfold forms are loaded onto
the tractor pins, with the leading edge
visible on the tractor.
3. Check for pieces of paper in the paper
path and under the platen.
4. If message remains, see MAP 0190:
Form feed problems.
1. If attachment card was removed,
confirm this by pressing the start key.
2. Otherwise, Turn off the printer and
reseat the attachment card.
Press Start to confirm installing a new
attachment card and to continue power on
initialization. After the code transfer is
complete, Coax or Twinax will be displayed
on the operator's panel.
Chapter 1. Diagnosing problems
83