2.6.13 Optional Paper Size Sensor
Before disassembling or reassembling, be sure to refer to "1. Before Disassembling or Reas-
sembling."
(1)
Remove the optional recording paper tray block. (Refer to "2.6.1 Optional Recording Pa-
per Tray Block.")
(2)
Remove the optional recording paper tray. (Refer to "2.6.2 Optional Recording Paper Tray.")
(3)
Remove the optional tray left cover. (Refer to "2.6.3 Optional Tray Left Cover.")
(4)
Remove the optional tray right cover. (Refer to "2.6.4 Optional Tray Right Cover.")
(5)
Remove the optional tray rear cover. (Refer to "2.6.5 Optional Tray Rear Cover.")
(6)
Disconnect the all connectors from the optional tray PBA.
(7)
Remove the two screws from the optional tray PBA plate, and remove the optional tray
PBA plate.
Optional tray PBA
DP120F/DP125F Removal/Replacement
Fig. 8-2-155
8-124
Optional tray
PBA plate
08-02-155