NEC Univerge SV8100 Features And Specifications Manual page 75

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
90-10-02
System Alarm Setup – Report
90-11-02
System Alarm Report – Report
Method
90-11-06
System Alarm Report – SMTP
Host Name
90-11-07
System Alarm Report – SMTP
Host Port Number
90-11-08
System Alarm Report – To Email
Address
90-11-09
System Alarm Report – Reply
Address
90-11-10
System Alarm Report – From
Address
90-11-11
System Alarm Report – DNS
Primary Address
90-11-12
System Alarm Report – DNS
Secondary Address
90-11-13
System Alarm Report –
Customer Name
90-11-14
System Alarm Report – Change
SMTP Client
Alarm Reports
Description/Comments
When enabled the system will
provide notification of events for
each of the enabled reports. This
does not have to be set for
DIMLast/DIMDump files to be
sent.
When Alarm Reports are to be
emailed, set this option to 1. This
program has higher priority than
Program 90-12-06.
When Alarm Reports are to be
emailed, set the SMTP name (for
example, smtp.yourisp.com).
Contact your ISP (Internet Service
Provider) for the correct entry if
needed.
When Alarm Reports are to be
emailed, set the SMTP host port
number. Contact your ISP
(internet service provider) for the
correct entry if needed.
When Alarm Reports are to be
emailed, set this email address to
which the report should be sent.
When Alarm Reports are to be
emailed, set the email address
where replies should be emailed.
When Alarm Reports are to be
emailed, set this email address for
the station sending the report.
When Alarm Reports are to be
emailed, set the DNS primary
address.
When Alarm Reports are to be
emailed, set the DNS secondary
address.
When Alarm Reports are to be
emailed, enter a name to identify
the particular system.
When enabled the system uses
the programs in 47-18-xx for email
server integration. This program
must be used for DIMLast/
DIMDump files to be sent. Note
you must have a PZ-ME50-US
mounted to the CCPU when using
this program.
Assigned Data
1
0 = Disabled
1 = Enabled
(default = 0)
0 = No Report
1 = Email Address
(default = 0)
Up to 255 characters
(default not assigned)
0~65535
(default = 25)
Up to 255 characters
(default not assigned)
Up to 255 characters
(default not assigned)
Up to 255 characters
(default not assigned)
0.0.0.0~
255.255.255.255
(default = 0.0.0.0)
0.0.0.0~
255.255.255.255
(default = 0.0.0.0)
Up to 255 characters
(default not assigned)
0 = Disabled
1 = Enabled
(default = 0)
Issue 13.0
Level
2
3
2 - 41