UNIVERGE SV8100
Program
Program Name
Number
14-01-02
Basic Trunk Data Setup –
Transmit Level
14-01-03
Basic Trunk Data Setup –
Receive Level
14-02-02
Analog Trunk Data Setup – Ring
Detect Type
14-05-01
Trunk Group – Trunk Group
Number
14-06-01
Trunk Group Routing – Priority
Order Number
Central Office Calls, Answering
Description/Comments
Customize the transmit and
receive levels of the CODEC Gain
Types for each trunk.
Customize the transmit and
receive levels of the CODEC Gain
Types for each trunk.
Set Extended Ring Detect or
Immediate Ring Detect for the
trunk. For T1 loop/ground start
trunks, this option must be set to 1
for the trunks to ring and light
correctly.
Assign trunks to trunk groups then
go to Program 14-06-01 below to
set up Trunk Group Routing.
Set the priority order number 1~4.
Assigned Data
1
Trunks 1~200
1~63
(-15.5 ~ +15.5dB in
0.5dB intervals)
[default = 32 (0dB)]
Trunks 1~200
1~63
(-15.5 ~ +15.5dB in
0.5dB intervals)
[default = 32 (0dB)]
Trunks 1~200
0 = Normal/delayed
1 = Immediate Ringing
(default = 1)
Trunks 1-200
Trunk Groups 1-100
Default = Trunks 1-200
assigned to trunk
group 1 with priorities
equal to the trunk
number.
Trunk 1 = Priority 1
Trunk 200 = Priority
200.
0 = Not Specify
1~100 : (Trunk Group
Number)
1001~1100 : (1000 +
Route Table Number)
Default:
Route 1, Order
Number 1 = 1 (Trunk
Group 1)
Order Numbers 2, 3, 4
= 0 (Not Specified)
All Other Routes
(2~100) and Order
Numbers (1~4) = 0
(Not Specified).
Issue 13.0
Level
2
3
2 - 269