Switch Settings
SWITCH NAME
SENSE
(Rotary SW)
F
4
NOTE 1
NOTE 3
MB (Toggle SW)
ON
NOTE 2
SW1
(Piano Key SW)
OFF
4
3
2
1
ON
JP0
(Jumper pin)
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
NOTE 3:
When accommodating the CIR card (PN-4RSTC-A) on Remote site, be sure to set SENSE switch
of all the CIR cards to AP Number 15. Also, set AP Number to any one between 64 and 93 by
CM05 for each CIR card. If a different site is used to accommodate the CIR card, be sure to set
SENSE switch to switch No. 15.
[Series 3800 software or later required]
SWITCH
SETTING
NUMBER
POSITION
4-F
Set the switch to match the AP Number (04-15) to be
set by CM05.
AP No.
04 05 06 07 08 09 10 11 12 13 14 15
SW No.
4
5
0-3
Not used
UP
DOWN
ON
1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
RIGHT
FUNCTION
6
7
8
9
A
For make-busy
For normal operation
For make-busy No. 0 circuit
For normal operation
For make-busy No. 1 circuit
For normal operation
For make-busy No. 2 circuit
For normal operation
For make-busy No. 3 circuit
For normal operation
For normal operation
– 466 –
PN-4RSTC/PN-4RSTC-A (CIR)
B
C
D
E
F
NWA-008841-001 Rev.5.0
NOVEMBER/15/2006
CHECK
90ch3003.fm