NEC NEAX 2000 IPS Installation Manual page 417

Internet protocol server installation procedure manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

SWITCH
NAME
SW3 (Dip SW)
ON
1 2 3 4
JPS (Jumper pin)
JPR (Jumper pin)
JP (Jumper pin)
The figure in the SWITCH NAME column and the position of
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SWITCH
SETTING
NUMBER
POSITION
1
ON
2
ON
3
ON
ON
4
OFF
RIGHT
LEFT
RIGHT
LEFT
UP
DOWN
FUNCTION
Always set to ON
Always set to ON
Always set to ON
When mounting this card on Remote
Site.
When mounting this card on Main Site.
TA is grounded on the transmission
line: 75 Ω (For coaxial cable)
Balanced transmission: 120 Ω
(For twisted-pair cable)
RA is grounded on the transmission
line: 75 Ω (For coaxial cable)
Balanced transmission: 120 Ω
(For twisted-pair cable)
Line impedance:
75 Ω (For coaxial cable)
Line impedance:
120 Ω (For twisted-pair cable)
– 401 –
PN-DAIF (DAIF)
in the SETTING POSITION col-
NWA-008841-001 Rev.5.0
CHECK
90ch3003.fm